What happens when the diesel generator automatically stalls? Huaquan Power will help you identify the problem.
1. Handling of diesel generator fuel depletion or fuel shut-off valve cutting off oil circuit: Check the fuel shut-off valve to see if it is open. If it is closed, it should be opened. Check if there is fuel in the fuel tank. If the fuel tank is empty, refuel
2. If so, the fuel quality is poor and needs to be checked and replaced.
3. The fuel delivery pipeline is leaking. Solution: Check for loose connections, broken pipes, loose filters, etc., and correct them one by one
4. Oil leakage in the internal or external oil transmission system. Solution: Conduct an external oil leakage inspection on all filters, gaskets, pipelines, and connectors. Use pressurization method to check for oil leakage in the internal oil circuit. Repair or replace
5. The fuel pump drive shaft is broken. Solution: Check if the drive shaft of the gear pump is broken. Re calibrate or replace
6. Improper adjustment or wear of throttle transmission rod. Solution: Check the wear condition, replace and adjust the transmission rod
7. The idle spring assembly is incorrect. Solution: Reinstall and adjust
Additionally, if there is a leak in the sealing gasket of the diesel generator, a pressure check is required to identify the leaking cylinder. Replace and repair. I hope the above introduction can be helpful to users.